ISO. Second edition. Reference number Permission can be requested from either ISO at the address below or ISO’s member body in the. 31 Jul Purchase your copy of BS EN ISO as a PDF download or hard copy directly from the official BSI Shop. All BSI British Standards. EN ISO Intravascular catheters – Sterile and single-use catheters – Part 5 : Over-needle peripheral catheters – ISO specifies requirements.

Author: Arashisho Moogukazahn
Country: Singapore
Language: English (Spanish)
Genre: History
Published (Last): 9 February 2015
Pages: 410
PDF File Size: 15.87 Mb
ePub File Size: 18.27 Mb
ISBN: 898-9-12900-481-3
Downloads: 44760
Price: Free* [*Free Regsitration Required]
Uploader: Dorn

Limited collection of colours. Iso 10555-5 designed for the introduction or withdrawal of liquids or devices into or from the peripheral vascular system.

Until that time, a manufacturer may label his product “radio- opaque” provided he can support this claim by demonstrat- ing that he has an iso 10555-5 method for showing radio- opacity. This Indian Standard has been developed from Iso 10555-5 No.: All standards are subject to revision, and parties to agreements based on this part of ISO are encouraged to investigate the possibility of applying the most recent editions iso 10555-5 the standards indicated below.

For the purpose of deciding whether a particular requirement of this standard is complied with, the final value, iso 10555-5 or calculated expressing the result of a test or analysis, shall be rounded off in accordance with IS 2: Review of Indian Standards Amendments are issued iso 10555-5 standards as the need arises on isso basis of iso 10555-5. E-5 Test report The test report shall contain at least the following information: Annex D shows examples of typical needle point geom- etries. The corresponding Indian Standards which are to be substituted in their places are listed below along with their degree of equivalence for the editions indicated: The catheter tube may have a single lumen or multiple lumens.

Available from Munsell 10555–5, N. When the needle is fully inserted into the catheter unit, the catheter tube shall neither extend beyond the heel of the needle bevel nor be nnore than 1 nnnn fronn it see dinnension a in iso 10555-5 1.

Attention is particularly drawn to the following: NOTE To improve the visibility of the solution, a colorant such as red or blue food dye may be incorporated. No part of the these publications may be reproduced in any form without the prior permission in writing of BIS.

Round the iso 10555-5 average water fiowrate to the nearest whole iso 10555-5 of millilitres. Users of Indian Standards should ascertain that they are in possession of the latest amendments or edition by referring to the latest issue of ‘BIS Catalogue’ and ‘Standards: This does not preclude the iso 10555-5 use, in the course of implementing the standard, of necessary details, such as symbols and sizes, type or grade designations. Add the following reference: Fixed or removable fitting per- mitting venting of iso 10555-5 while restricting iso 10555-5 preferably preventing the escape of blood.

The assembly comprising at least a needle tube attached to and communicating with a needle hub.

The fluid is allowed to flow into the needle, and the time taken for fluid to iso 10555-5 through the vent fitting is measured. International Standard ISO The fluid pathway in the needle shall be free of unintended obstructions that would prevent flashback. Part 1 General requirements do The iso 10555-5 committee has reviewed the provisions of the following International Standard referred in this adopted standard and has decided that it is acceptable for use in conjunction with this standard: Other parts of this standard are as follows: I Principle Water is allowed iso 10555-5 flow through the catheter and the amount of flow is measured either volumetrically or gravimetrically.

In this adopted standard, reference appears to certain International Iso 10555-5 for which Indian Standards also exist.

BS EN ISO 10555-5:2013

Copyright BIS has iso 10555-5 copyright of all its publications. Designation and catalogue of CCR colours. The details of conditions under which the licence for the use of the Standard Mark may iso 10555-5 granted to manufacturers or producers may be obtained from the Bureau of Indian Standards.

Blood flow into the needle hub.

Page 3, subclause 4. Iso 10555-5 tested in accordance with annex Iso 10555-5, fluid shall not leak out of the vent fitting within 15 s. Rigid tube with one end sharpened to facilitate entry into body tissue.

At the time of publication, the editions indicated were valid. Peripheral intravascular catheter designed for the introduction of withdrawal of liquids or devices into or from the iso 10555-5 vascular system.

Assembly 105555-5 the cath- eter tube, iso 10555-5 hub and any integral fittings. Details of which is given in National Annex A.

Measure iso 10555-5 time taken for fluid to form the first falling drop at the back of the vent fitting. If a steel tube is used, it shall connply with ISO Certain conventions are, however, not identical to those used in Indian Standards. An example of a suitable apparatus is shown in fig- ure 1055-5. An approved test method for producing a iso 10555-5 of radio-detectability will be established.

Intravascular catheters ISO , -3, -4, -5

Search the history of over billion web pages on the Internet. Bureau of Indian Standards BIS is a statutory institution established under the Bureau of Indian Standards Act, isoo promote harmonious development of the activities of standardization, marking and quality certification of goods and attending jso connected matters in the country. I Principle A force is applied successively tensile and connpress- ive iso 10555-5 the needle tube and needle hub and the tube- hub union is then examined for loosening.

NOTE 3 The point should be designed to be noncoring. Figure 1 iso 10555-5 Typical over-needle peripheral intravascular catheter NOTE 2 At the time of publication of this part of ISOthere is no acceptable, iso 10555-5 test method to determine radio-detectability. The number iso 10555-5 significant places retained in the rounded off value should be the same as that of the specified value in this standard. Suggested colour references for opaque naaterials are given in annex C.